    PRODUCTION FACILITY
    KARALTAY SCIENTIFFIC INSTRUMENTS CO., LTD.
    Room 1015,Beijing Research Institute of Meha-
    nical & Electrical Technology,No.18 Xueqing Road,
    Haidian District,
    Beijing,P.R. China 100083
    Tel:+86-10-62023948
    Fax:+86-10-62016954
    E-mail:sals@karaltay.com

    WFX-310/320 Flame Atomic Absorption Spectrophotometer

    FEATURES:

    1 High cost-effctive flame AAS

    Reasonable design, adopting the same key parts as in high end instruments, ensures basic functions but less automation to provide an economic model for users

    2 Reliable integration of main unit with microprocessor

    Built-in microprocessor with necessary auto-control and data processing functions achieve high reliability of the instrument

    3 Simple and easy operation

    Eye-catching digital display, multi-function data processing ability and fast function-key direct input realize easy and fast analysis

    SPCIFICATIONS:

    Specification

    Wavelength range

    190-900nm

    Wavelength accuracy

     í└0.5nm

    Resolution

    Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%.

    Baseline stability

    0.005A/30min

    Background correction

    The D2 lamp background correction capability at 1A is better than 30 time

    Light Source System

    Lamp turret

    2 lamps are powerd simultaneously (one preheated)

    Lamp current adjustment

    0~20mA

    Lamp power supply mode

    400Hz square wave pulse;

    Optical System

    Monochomator

    Single beam, Czerny-Turner design grating monochromator

    Grating

    1800 l/mm

    Focal length

    277mm

    Blazed Wavelength

    250nm

    Spectral Bandwidth

    0.1nm, 0.2nm, 0.4nm, 1.2nm, automatic change

    Adjustment

    Manual adjustment for wavelength and slit

    Flame Atomizer

    Burner

    10cm single slot all-titanium burner

    Spray chamber

    Corrosion resistant all-plastic spray chamber

    Nebulizer

    High efficiency glass nebulizer with metal sleeve, sucking up rate:6-7ml/min

    Position adjustment

    Manual adjusting mechanism for vertical, horizontal positions and the rotation angle of the burner/min

    Gas line protection

    Fuel gas leakage alarm/min

    Detection and Data Processing System

    Detector

    R928 Photomultiplier with high sensitivity and wide spectral range.

    Electronic and micro-computer system

    Automatic adjustment of light source power. Light energy and negative high-voltage auto-balance

    Display mode

    LEC display of energy and measurement values, concentration direct reading.

    Read mode

    Transient, time average, peak height, peak area, integral time is selectable in the range of 0.1~19.9s.

    Scale expansion

    0.1~99

    Data processing mode

    Automatic calculation of mean, standard deviation and relative standard deviation. Reporting number is in the range of 1~99

    Measurement mode

    Automatic cureve fitting with 3~7 standards; Sensitivity auto-correction

    Result printing

    Measurement data, working curve, signal profile and analytical conditions can all be printed out

    Instrument self-check

    Check current status of each function key

    Characteristic Concentration and Detection Limit

    Air-Acetylene

    Cu: Characteristic concentrationí▄0.025mg/L, Detection limití▄0.006mg/L;

    Function Expansion

    Hydride vapor generator can be connected for hydride analysis

    Dimensions and weight

    Main unit

    102í┴49í┴54cm, unpacked 80kg